1.1 working pressure
the working pressure of the outer container is usually between 0.5kpa and 1.0kpa. when the user makes clear regulations, it shall be implemented in accordance with the user's requirements.
1.2 design pressure
the design pressure of the outer vessel is determined according to its working pressure, which is generally between 1.0kpa and 2.0kpa. when the user makes clear provisions, it shall be implemented in accordance with the user's requirements.
1.3 operating temperature
the working temperature of the outer container is the ambient temperature.
1.4 design temperature
the design temperature of the outer container is 50 ℃.