anti eccentricity design of lng air temperature gasifier


during the operation of the air heated gasifier, the gasifier itself is subject to two different directional forces: its own gravity and gas buoyancy (other wind forces are not considered);


the liquid inlet section adopts 8 fins, the heating section adopts 12 fins, and the weight of 12 fins is greater than 8 fins; generally speaking, gravity is greater than buoyancy; however, the buoyancy of the liquid inlet end is small, and the frosting during operation increases the gravity, so the center of gravity will shift slightly to the liquid inlet end.


generally, when the design can ensure continuous operation without icing, try to use more 12 fins in the reheating section, so as to balance the gravity and keep the center of gravity in the center of the equipment as far as possible, so as to prevent adverse effects such as equipment inclination doer to different forces during operation.